Feature of mounts
neumatic elastomeric mounts isolation the vibratiom and
shock of the machine form the floor.It can also reduce the
influences from the other machine. BEtter parts fishes and
high quality from vibration reduction. It elminates the noise
transferred from the floor or due to the resonance of building.
Machine are stationary on the floor wlthout anchors.
Therefore the installation cost and time can be greatly saved.
The layout can be easily changed to inprove the productivity.
Machines can set up on the second floor.
Application
Application
Precision machine tool,Coordinate measuring machines,
Accurate test bed,100/min-500/mln Punch.Air compressor,
Air pump and required special vibration isolation of equipments.
How To lnstalI
How to install
Place the mounts under the anchor of the machine,lnsert
center bolt and engage threads in mount. Hand tightening is
adequate at this point. Sequentially pressurzation of isolator
rhtough valve until dimension is 3 mm for each mount. Tighten
the nuts. Continue sequential pressurization of each mount so
that dimension is 7 mm,Then adjust the level of machine. Check
each mount for overall height which should be within H¡À6mm.
Whenever machine is to be removed from mounts,Deflate
mounts before removal of load. |